Parameter-Efficient 12-Lead ECG Reconstruction from a Single Lead

The 28th International Conference on Medical Image Computing and Computer Assisted Intervention (MICCAI 2025), Acceptance rate 29%, Daejeon, Korea, pp. 431–441, 2025, doi: 10.1007/978-3-032-04937-7_41.

Junseok Lee, Yeonho Yoo, Jinkyu Kim, Dosun Lim, Gyeongsik Yang, Chuck Yoo

Download PDF

Abstract

With the rise of wearable IoT devices such as smartwatches and smart rings, ECG signals have become more accessible and made cardiovascular monitoring a reality. However, analyzing the ECG signals for complex conditions, such as bundle branch blocks and myocardial infarction, requires multi-lead ECG data. Although various deep learning models for ECG reconstruction have been proposed, they are computationally expensive and unsuitable on resource-constrained wearable IoT devices. To address this challenge, we propose mEcgNet, a parameter-efficient model for reconstructing 12-lead ECG signals from a single lead. mEcgNet introduces a modular deep learning architecture for parameter efficiency and separates the single lead-I signal into multiple frequency segments to improve accuracy. Our experiments demonstrate that mEcgNet significantly reduces the number of parameters and inference time by ∼23.1× and ∼5.4×, respectively, compared to existing state-of-the-art models. Furthermore, it reduces the reconstruction error by ∼22.1%, demonstrating its high accuracy and efficiency.

Paper summary

Reconstruct more leads with a smaller model

Separating an ECG into frequency bands helps a compact model reconstruct twelve leads from one measured lead.

A single ECG lead is easier to collect, but it does not directly provide the twelve views used in a standard ECG. mEcgNet reconstructs those views while reducing the model size and computation required by earlier reconstruction networks.

Give each frequency band an appropriate module

The input lead is separated into low-, medium- and high-frequency signals using Fourier transforms. Three sequential reconstruction modules process those signals, passing earlier outputs to later modules. Smaller modules handle the first two bands; a larger module handles the high-frequency component.

The model assigns capacity according to each signal component.

Frequency-separated signals pass through sequential reconstruction modules to produce twelve ECG leads.View full-size figure
Frequency-separated signals pass through sequential reconstruction modules to produce twelve ECG leads.

Compare reconstruction error and inference cost

The authors evaluate PTB-XL and Chapman-Shaoxing with five-fold cross-validation and reproduce EKGAN and ECGrecover on the same datasets. On PTB-XL, mean squared reconstruction error is 0.113 for mEcgNet, 0.120 for EKGAN and 0.145 for ECGrecover. On Chapman-Shaoxing, the corresponding errors are 0.109, 0.123 and 0.120.

mEcgNet uses 1.13 million parameters and 0.84 GFLOPs for reconstruction. CPU-only inference on a Jetson Orin Nano takes 17.99 ms per ECG; EKGAN and ECGrecover take 1.4 and 5.4 times as long, respectively.

Mean squared reconstruction error on PTB-XL; lower is better.
ModelMSE
mEcgNet0.113
EKGAN0.120
ECGrecover0.145

Classification from reconstructed ECGs

In a separate test, the same classifier receives either an observed 12-lead ECG or the reconstruction. Mean F1 over six conditions is 0.70 with the observed signal, 0.66 with mEcgNet, 0.53 with EKGAN and 0.26 with ECGrecover.